Important safety instructions

Read this before installing or servicing the unit.

Mains power. The unit is powered from a grounded mains outlet. Connect it only to an outlet with a protective earth connection, and do not defeat the ground pin on the power cord.

Isolating the unit. The rear mains switch de-energizes the chassis but does not disconnect it from the supply. Unplug the power cord before opening the fuse holder in the mains switch housing.

Hot surfaces. The top cover forms part of the cooling path and reaches up to 48 °C (118 °F) in normal operation. Allow the unit to cool before handling it, and do not rest anything on it.

Airflow. Do not block the front panel intake or the right-side exhaust. Do not fit a door or blanking panel that seals against the front of the unit.

Fuse replacement. Replace the mains fuse only with one of the same type and rating: 2 A, 250 V AC, fast blow, 5 x 20 mm glass cartridge. Section 4.2 gives the procedure. The fuse holder is on the outside of the rear panel, so replacing the fuse does not involve opening the chassis.

DC inlet. The DC screw type jack on the rear panel is not a supported power input. Do not connect anything to it.

Rack mounting. Mount the unit in a standard 19-inch rack with four screws and cage nuts, two each side. It is supported by its front mounting alone.

Servicing. The mains fuse is the only user-replaceable part. There are no user-serviceable parts inside the chassis, so do not remove the cover. Refer all other servicing to Ai-Media support.

1. Introduction

1.1 About this manual

This manual covers the installation, configuration and day-to-day operation of the AI-Media UHD592 caption encoder. It is written for broadcast engineering staff who will rack, commission and operate the unit.

The manual is organized in the following order: what the unit does, how to install it, how to bring it onto the network, then a reference for each of its two operating surfaces and for the caption workflows it supports. If you are commissioning a unit for the first time, read sections 2 and 3 in order, then bring the unit onto the network using the front panel network menu in section 7.3.1.

Checking your software versions

The unit reports its own software, firmware and operating system versions. Read them at the front panel under System Setup > Version, in the web interface under System > System Info, or through the REST API with GET /api/v1/system/general_info. This manual describes how the product behaves rather than any one release, so it stays correct as the software is updated.

Conventions used in this manual

Convention Meaning
Menu > Item A path through the front panel menu or the web interface
Bold A control, button or field label exactly as it appears on the product
Monospace A value you type, a file name, or text the unit displays
Note Information that helps you avoid a wrong assumption
Caution An action that can interrupt on-air output or lose configuration

1.2 What the UHD592 does

The UHD592 places closed captions into a live video signal so that viewers who are deaf or hard of hearing can follow programming. With LEXI Voice, it can also carry live AI voice translation, so the same program can reach audiences who speak other languages.

It sits in the SDI path of a live broadcast or streaming chain. Video passes through the unit, and the encoder inserts CEA-608 and CEA-708 caption data into the ancillary space of the outgoing signal. The caption text itself can come from several places:

  • AI-Media LEXI, the automatic captioning service, running in the cloud or on an on-premises LEXI server
  • The iCap network, which is how live human captioners connect to the encoder
  • A directly connected caption source on one of the two serial ports
  • Upstream captions already present in the incoming signal, which the unit can pass through, block or replace

The unit also contains a caption decoder. This is a monitoring tool: it decodes the captions carried in a signal and renders them into a separate SDI output so an operator can see on-air captions on a confidence monitor without needing a separate decoder.

The LEXI services. The unit works with three LEXI services, which can run alongside one another:

Service What it does
LEXI Text Automatic live captioning. Speech in the program audio becomes caption text, which the encoder inserts into the outgoing signal.
LEXI Translate Automatic real-time language translation. It works with LEXI Live captioning to translate what is said as it is said, so a translated transcript is produced without a human interpreter in the loop.
LEXI Voice AI live voice translation. It produces synthesized speech in another language from the live program audio.

LEXI Voice. Voice output is delivered over the same iCap network that already carries captions and is embedded in the existing signal path, so it needs no additional equipment and no separate cloud connection.

Each voice output is tied to a caption service, and both are configured per channel in the web interface. Typical uses are live sports, conferences and keynotes, and streaming, OTT services.

Note. Captions and voice translation answer different obligations and are not alternatives. Voice translation widens the audience a program can reach. Captions are what broadcasters need to meet captioning regulations, for example FCC rules in the United States and CRTC rules in Canada, and enabling LEXI Voice does not reduce that requirement.

1.3 Where it fits

The UHD592 is a 1RU rack-mounted unit for broadcast facilities, playout centers and production trucks, operated by broadcast engineers rather than by members of the public.

It is operated in two ways, and the difference matters throughout this manual:

  • The front panel, which carries a character display, a six key keypad and status indicators. The front panel is used for network configuration, security mode, caption appearance settings and video generator controls. It is also the surface you reach when the network is unavailable.
  • The web interface, reached over the network from an ordinary browser on your own computer. This covers channel and caption configuration, audio configuration, iCap and LEXI setup, monitoring, logs, licensing, user management and software update.

Neither surface is a complete substitute for the other. Section 7 lists which functions live were.

1.4 Key features

Video Two SDI inputs and three SDI outputs, each up to 12 Gb/s, on HD-BNC connectors.
Caption standards CEA-608 and CEA-708, carried in the HD vertical ancillary data; OP-47 teletext. SD Line 21 and OP-42 are not supported.
Bypass Relay Hardware relay bypass linking the main and auxiliary outputs to their respective inputs.
Caption sources LEXI automatic captioning, the iCap network, serial input, upstream captions.
Voice LEXI Voice live translation, one concurrently enabled output, delivered over iCap. Up To 5 Voice Channels
Monitoring Built in caption decoder with configurable CEA-708 font, size and opacity.
Audio Mini XLR analog audio input; up to 16 channels of embedded SDI audio.
Control Web interface, front panel, and a documented REST API.
Network Two Ethernet ports, both of which give full access.
Automation 8 GPI inputs and 8 GPO outputs; two serial ports.

1.5 Models

The UHD592 is sold as the LEXI Text Encoder. The web interface identifies itself according to the model it is running on, so this unit reports as the LEXI Text Encoder throughout.

1.6 What is in the box

  • The UHD592 unit. The rack ears are part of the front panel and are not removable, so there is no mounting bracket to fit.
  • A mains power cord, 3 feet, terminated in an IEC C13 connector. The plug on the other end matches the region the unit is shipped to.
  • A card carrying a QR code that links to the AI-Media support page for the UHD592.
Note. No printed manual ships in the carton. The QR code card when scanned, navigates to the Help Center, where the documentation is published electronically.
Note. No video or audio cables or adapters are included. The SDI connectors are micro-BNC, also called HD-BNC, and the audio input is a 3 pin mini-XLR. If your facility is wired with standard BNC or full-size XLR, have adapters or new cables ready before installation. See sections 3.6 and 3.7.

2. Installation

2.1 Before you begin

You will need a standard 19-inch equipment rack, a grounded mains outlet, SDI Video, network and audio cabling from your facility. The unit ships with a 3-foot IEC C13 power cord; see section 1.6 for the regional variants.

Before choosing a rack position, see section 2.5. Mounting height determines how easily operators can reach the front panel, so settling it at the start keeps installation simple.

2.2 Operating environment

Inlet air temperature 18 °C to 27 °C (64.4 °F to 80.6 °F)
Humidity 10% to 90%, non-condensing

The inlet temperature range follows the ASHRAE recommendation for equipment room air. The unit will run outside this range.

Note. The component most sensitive to sustained heat is the video control board, which enters a warning condition above an internal temperature of 65 °C (149 °F). That temperature is not readable from the front panel or the web interface, so keep the inlet air within the range above rather than relying on the unit to warn you.

2.3 Airflow and clearance

Air is drawn in through the front panel and exhausted through the right side and the rear of the chassis.

Because the intake is at the front and the exhaust is at the side, the unit does not follow a pure front to back airflow scheme. When planning the rack:

  • Leave the front panel intake unobstructed. Do not fit a blanking panel or a door that seals against the front of the unit.
  • Leave the right side of the chassis clear of any solid obstruction. In a rack with side panels, allow the normal internal side clearance rather than packing equipment tightly against the unit.
  • Leave the rear clear for both exhaust and cabling.

AI-Media does not publish a specific clearance dimension for this product. Observe the nominal airflow clearance your rack manufacturer specifies for general purpose 1RU equipment and keep the front intake and the right-side exhaust unobstructed.

2.4 Rack mounting

Height 1 rack unit, 1.75 inches / 4.5 cm
Width 19 inches / 48.25 cm
Depth 10 inches / 25.4 cm
Weight 6.5 lb. / 3 kg
Chassis material Aluminum alloy 5052-H32

The rack ears are part of the front panel and are not removable. There is no separate bracket to fit and no rear support kit; at 10 inches deep and 3 kg the unit is supported by its front mounting alone.

To mount the unit:

  1. Decide on the mounting height. See section 2.5.
  2. Offer the unit into the rack and align the ear slots with the rack rail holes.
  3. Fit four screws and cage nuts appropriate to your rack, two each side. Tighten evenly; do not overtighten into the aluminum ears.
  4. Confirm the front panel intake and the right-side exhaust are clear.

2.5 Choosing a mounting height

AI-Media does not specify a mounting height. Choose one that suits your rack and room, keeping in mind that it determines who can reach and operate the front panel.

For an installation that needs to be reachable by people using a wheelchair, mount the unit so that the front panel display and keypad fall between 400 mm and 1200 mm (15 and 48 inches) above the finished floor. That range satisfies both the unobstructed forward and side reach requirements of Section 508 407.8 and of EN 301 549 clauses 8.3.2 and 8.3.3 of VPAT.

If the unit must be mounted outside that range, operators can run it day to day from the web interface on any computer on the network. Initial network setup is the exception: it is done at the front panel during commissioning (section 7.3.1), so make sure the panel can be reached for that step.

2.6 Power

Mains inlet IEC 60320 C14
Mains supply 115 / 230 V AC, 50 / 60 Hz
Mains fuse 2 A, 250 V AC, fast blow, 5 x 20 mm glass cartridge
DC inlet DC screw type jack, fitted but not for use
Power consumption 80 W typical
Power factor 0.97
Power cord supplied 3 feet / 0.9 m, IEC C13. The plug matches the region the unit is shipped to

The unit is powered by the IEC mains inlet.

Caution. A DC power screw type jack is fitted on the rear panel. It is reserved for possible future use and is not a supported way to power the unit. Do not connect anything to it.

Connect the unit to a grounded outlet. In a facility with a UPS or a protected technical power circuit, use it: the relay bypass protects the video path when the unit loses power, but the encoder stops inserting captions until power is restored.

2.7 Acoustic noise

The unit has three 40 mm axial fans behind the front panel and one internal blower on the CPU cooler. The blower speed varies with processor load and inlet air temperature, so noise rises and falls with what the unit is doing.

Condition Sound pressure
Idle 35.1 dBA
50% load 44 dBA
100%, briefly during power up 62 dBA

These are calculated upper-bound figures for an open chassis rather than measurements of an assembled unit in a rack.

The unit is intended for equipment rooms and racks rather than for occupied control room positions. If it must be installed near a person working, take the 50% load figure as the realistic steady state.

3. Rear panel and connections

3.1 Layout

Viewed from the rear, the panel runs in this order from left to right:

Position Connector Section
1 Mains inlet and power switch 3.2
2 Two 3.5 mm audio jacks, green and pink, not used 3.9
3 Two DisplayPort sockets
4 Product label, AI MEDIA and the unit serial number
5 LAN 1 and LAN 2 3.3
6 USB Type A ports 3.4
7 DC inlet, circular screw type, not used 3.9
8 RS 232/422 P1 and RS 232 P2 3.5
9 MAIN IN, OUT 1, OUT 2, AUX IN, AUX OUT 3.6
10 AUDIO IN 3.7
11 GPIO, marked IN and OUT 3.8

Every connector that carries a printed label is in use. The two unlabeled 3.5 mm jacks and the DC inlet are not; see section 3.9.

DisplayPort. The two DisplayPort sockets drive an external monitor. They are provided for diagnostics carried out under instruction from Ai-Media support and are not used in normal operation.

3.2 Power

The mains inlet is an IEC 60320 C14 with an integral rocker switch marked I and O. Supply 115 or 230 V AC at 50 or 60 Hz. See section 2.6 for consumption and cord details.

This rocker is the hard disconnect and de-energizes the whole chassis. It is not the control used to shut the unit down in normal service; that is the POWER control on the front panel, which places the unit on standby. See section 4.2 about how the two work together.

3.3 Network

Connectors Two RJ-45, labeled LAN 1 and LAN 2
Speed 10/100/1000BASE-T

Either port gives full access to the web interface and the API. There are no management port and no data port; the two are interchangeable, and you may use one or both. In the software, the interfaces appear as lan1 and lan2.

Note. Do not put both ports on the same subnet. Two interfaces with addresses in the same range can make the unit unreachable or reachable only intermittently, because return traffic may leave by the wrong port. Use separate subnets or use one port only.

3.4 USB

Four USB 3.0 Type A ports are available, directly below the network connectors.

The ports are provided with a keyboard during diagnostics and, if ever required, for a local software update. Apply software updates through the web interface rather than from USB; see the UHD592 web interface manual.

3.5 Serial ports

Port Label Modes
P1 RS 232/422 P1 RS-232 or RS-422, selectable
P2 RS 232 P2 RS-232 only

Both are 9 pin D subminiature connectors. The mode of P1 is set at the front panel; the options are listed in section 7.3.5.

Checking the unit over a serial connection. A terminal attached to a serial port can query the encoder's state and firmware using the Smart Encoder command set. Connect at 1200 baud, 7 data bits, odd parity, 1 stop bit. Commands are entered as Ctrl-A followed by a letter, a number or a string.

Note. Most of what the Smart Encoder commands report is also available through the REST API, documented in the Help Center, which is the route to prefer for new work. The serial command set is retained for compatibility with existing installations and equipment.

3.6 Video

Five micro-BNC connectors carry the SDI signal path. Micro BNC is sometimes called HD-BNC.

Note. The HD492 used standard BNC connectors. The UHD592 uses micro-BNC, which allowed its circuit boards to be made smaller. If you are replacing an HD492 with a UHD592, have micro-BNC cables or BNC-to-micro-BNC adapters ready before you begin. Existing HD492 cabling will not connect directly.

Appendix B lists the video standards the unit has been tested against and what each surface reported on each one.

Label Direction Function
MAIN IN Input Primary program input
OUT 1 Output Primary program output, captions inserted
OUT 2 Output Second copy of the primary output
AUX IN Input Auxiliary input
AUX OUT Output Auxiliary output

 

Standards HD-SDI (SMPTE 292M), 3G-SDI (SMPTE 424/425M), 6G-SDI (SMPTE ST-2081), 12G-SDI (SMPTE ST-2082). SD-SDI is not supported.
Formats 720p 50, 60 · 1080i 50, 60 · 1080PsF 24, 25, 30 · 1080p 24, 25, 30, 50, 60 · 2160p 30, 50, 60
Color sampling 4:2:2 YCbCr
Signal conditioning Adaptive equalizer and reclocker
Rate detection Automatic

Relay bypass. The main and auxiliary outputs are linked to their respective inputs by a hardware relay. When the unit loses power, or when the front panel bypass switch is engaged, the relay closes and video passes straight through with its existing ancillary data intact. Plan your cabling so that the bypass path carries the signal you need on air: MAIN IN bypasses to the main output, and AUX IN bypasses to the auxiliary output.

Note. Any AUX IN video will not pass when the UHD592 is using the Main Decoder out function. Bypass will switch to the AUX IN video.

3.7 Audio

Connector AUDIO IN, 3 pin mini-XLR
Format Balanced analog audio

Analog audio is the only external audio input. Program audio embedded in the SDI signal is also available to the encoder and is selected in the web interface; see the UHD592 web interface manual.

3.8 GPI and GPO

The GPIO block carries two 16 pin IDC connectors. The upper connector, marked IN, provides eight general purpose inputs. The lower connector, marked OUT, provides eight general purpose outputs. Each mate with a female IDC-16 connector.

The pin assignments are the same as those of the HD492, so an existing HD492 GPIO loom can be reused.

3.8.1 GPI, the upper connector

Each input is activated by closing contact between its pin and any ground pin. All odd numbered pins are ground.

Pin Function Pin Function
1, 3, 5, 7, 9, 11, 13, 15 Ground 10 GPI-E
2 GPI-A 12 GPI-F
4 GPI-B 14 GPI-G
6 GPI-C 16 GPI-H
8 GPI-D

To use an input, wire a dry contact closure, such as a relay contact or a latching push button, between the input pin and an adjacent ground pin. No external voltage is required.

3.8.2 GPO, the lower connector

Each output is a single pole single throw relay presenting a pair of dry contacts. There is no voltage on the contacts; you supply the circuit.

Output Pins Output Pins
1 15, 16 5 7, 8
2 13, 14 6 5, 6
3 11, 12 7 3, 4
4 9, 10 8 1, 2

 

Contact type SPST relay, dry contacts
Nominal switching capacity 2 A at 30 V DC, resistive load
Caution. The switching capacity is for a resistive load. An inductive load such as a relay coil, a solenoid or a motor draws a large current on switch off and will shorten contact life or weld the contacts unless you fit a suppression diode or snubber across the load.

3.8.3 Example, driving an indicator lamp from a GPO

To light an LED when an output closes, take output 1 on pins 15 and 16:

  1. Connect a +12 V DC supply to pin 16.
  2. Connect pin 15 to the anode of the LED.
  3. Connect the cathode of the LED through a current limiting resistor to the ground of the same supply.

When the encoder asserts output 1, the relay closes, the circuit completes and the LED lights. Size the resistor for the LED forward voltage and the supply and keep the total current inside the 2 A contact rating.

3.9 Connectors that are not used

Two connectors on the rear panel are present because of the hardware they sit on, and have no function in this product:

  • The two 3.5 mm audio jacks, green and pink, beside the mains inlet. These belong to the motherboard audio subsystem. Do not connect program audio to them. The audio input for this product is the AUDIO IN mini XLR; see section 3.7.
  • The circular DC inlet. A DC screw type jack is fitted but is not a supported way to power the unit at this time. Do not connect anything to it. See section 2.6.

4. Front panel

4.1 Layout

From left to right the front panel carries:

Position Item Section
1 Rack ear, integral to the panel 2.4
2 AI MEDIA · LEXI TEXT ENCODER branding
3 Three fan grilles, the cooling air intake 4.7
4 ACTIVE control and its indicator 4.3
5 POWER control and its indicator 4.2
6 Status indicators VID, ICAP, CC, LEXI 4.4
7 Character display, with the model name UHD592 above it 4.5
8 Navigation keypad 4.6
9 Rack ear (Non Removable) 2.4

4.2 Power and standby

The unit has two power controls in different places, and they do different things.

Control Location Type Shows its state by Effect
Mains switch Rear, integral to the IEC inlet Latching, illuminated Illuminated when on De-energizes the whole chassis
POWER Front panel Non latching LED illuminated when on Places the unit in standby, or powers on the system.

The front POWER control behaves like the power button on a desktop computer. Pressing it does not disconnect the unit from the mains: it shuts down the electronics while the power supply stays on standby. Because the control does not latch, it returns to rest after each press and its position does not tell you the state of the unit. The POWER LED is illuminated when the unit is running.

The rear mains switch is a hard disconnect. Use it when you need the chassis fully de-energized, for example before working on the rear cabling. It is illuminated when on.

Replacing the mains fuse. The fuse sits in a holder inside the mains switch housing on the rear panel, behind a small cover. With the power cord unplugged, ease the cover open with a small flat blade screwdriver, slide out the holder, and fit a replacement of the same type: a 2 A, 250 V AC fast blow glass cartridge fuse, 5 x 20 mm. Close the cover before reconnecting the cord.

Caution. Unplug the power cord before opening the fuse holder. The rear mains switch de-energizes the chassis but leaves the inlet connected to the supply. Fit only a fuse of the same type and rating; a higher rated or slow blow fuse removes the protection the original provides.

To shut the unit down completely:

  1. Press the front POWER control and wait for the unit to shut down.
  2. Set the rear mains switch to O. Its illumination goes out.
  3. If required, unplug the mains cord.

4.3 The ACTIVE control and relay bypass

ACTIVE controls the SDI video path. It engages and releases the hardware relay bypass described in section 3.6. When bypass is engaged, the main input is connected straight through to output 1, and the encoder is out of the signal path.

Bypass also engages on its own whenever the unit loses power, so the video path survives a power failure or a chassis shutdown.

ACTIVE is a single pole single throw rocker with two resting positions:

Switch position State ACTIVE indicator Display
Depressed to the left Encoder in the video path Lit Normal status screen
Depressed to the right Bypassed Unlit BYPASSED

Because the rocker holds its position, you can tell which state the unit is in by feel as well as by eye, without moving the switch. When the encoder is in the video path, a blue LED beside the switch is lit.

Note. The indicator is unlit when the unit is bypassed, which is also how it looks when the unit has no power. If you find the indicator dark, check the switch position and the display before assuming the unit is off: while bypass is engaged the display reads BYPASSED in capitals.
Note. Bypass engaged from the front panel cannot be overridden in software. If the web interface reports the unit as bypassed and nobody set it there, check this switch.

4.4 Status indicators

Four indicators sit between the POWER control and the display.

Indicator State Meaning
VID Green Video signal present on the input
Red No video signal detected
ICAP Green Connected to iCap. This covers both an active session and a connection with no session running
Red Connection error: the network is down, or iCap reported an error
Unlit Not connected. Includes connecting, logging in, and disabled
CC Green A local caption source is actively feeding captions, from iCap, LEXI or a serial port
Unlit No local caption source is active
LEXI Green LEXI is running and connected, and captioning normally
Amber LEXI is in standby or ready. This covers a job that the server has terminated while LEXI itself is still running
Red A LEXI connection is being established, or there is a problem with the connection (Log-in Creds). Often brief, and it clears on its own once the connection settles
Unlit LEXI is off
Note. VID is never dark while the unit is running. A missing input shows red rather than going out, so a dark VID indicator means the unit is not powered, not that the feed is absent.
Note. An unlit ICAP indicator is not the same as a red one. Unlit covers the ordinary states of connecting, logging in, and being disabled. Red is reserved for a genuine fault: the network path is down, or iCap returned an error. If you are waiting for a connection to come up, expect unlit, then green.
Note. LEXI red is about the connection, not about captioning. It appears while a connection is being established or when the connection is establishing, and it frequently resolves itself within a few seconds. Treat a persistent red as a connection fault and check the LEXI: status message on line 2 or 4 of the display, which names the state.

4.4.1 Indicator behavior

The table above describes what the indicators do. Two items are worth knowing about, and each has a reliable alternative you can read instead. Both are a property of the indicators themselves rather than defects: the display carries the same state in text, so the panel does not depend on color alone.

Item What happens Read this instead
VID distinguishes its two lit states by color Green for a signal present, red for none, and never unlit while the unit is running, so the indicator alone separates the two only by color. The video format on line 1 of the display. A blank field means no signal on that input.
LEXI distinguishes three lit states by color Green for running, amber for standby or ready, red for a connection being established or in trouble, so the indicator alone separates the three only by color. The LEXI: status message on line 2 or 4, which names the state. The web interface also reports the LEXI state in text.

Each indicator can be read without color. CC is either lit or unlit. For ICAP, VID, and LEXI, the display shows the same information in text: iCap status on line 2, each input’s detected format on line 1, and the LEXI state on line 2 or 4. The web interface and REST API also report every indicator state in text.

4.5 The display

Type Blue backlit character LCD, light characters on a dark field
Size 20 characters by 4 lines
Active area 1 inch by 3 inches, 2.54 cm by 7.6 cm
Character height 4.75 mm on an uppercase letter

At rest the display shows a status screen laid out as follows:

Line Content
1, left Primary video input
1, right Auxiliary video input
2 Status of the iCap connection, or of test captions: iCap: or Test cap:
3 Closed caption status
4 LEXI state, shown as LEXI: while LEXI is running

The photographs below show the display in three states, with the POWER and ACTIVE indicators lit.


Two video inputs connected, LEXI actively captioning.


One video input connected, LEXI reporting an error.


One video input connected, LEXI active and waiting for dialog.

On seeing CC: F1 UPSTRM BLOCK: this is not an error. See the Help Center.

Every message the status lines can show is listed in section 4.5.1.

Character size is fixed and cannot be enlarged. Contrast and backlight are adjustable at the panel; see section 7.3.3.

4.5.1 Status messages

These are the messages the status lines can show and the condition that produces each one.

iCap connectivity, line 2

Message Condition
LAN disconnected No network connection is available to the unit
iCap: ERROR iCap reported an unrecognized or error condition
iCap: ACTIVE An iCap channel, S1 or S2, is actively transmitting
iCap: READY Connected to the iCap network and ready to transmit
iCap: CONNECTING Establishing or restoring the connection to iCap
iCap: DISABLED The iCap service is not running
Test cap: ACTIVE Test captions are running. See section 7.6.1

LEXI captioning, lines 2 and 4

Message Condition
LEXI: ERROR LEXI reported an error
LEXI: ACTIVE A LEXI captioning job is running
LEXI: READY A LEXI job is starting, was just created, or is ending
LEXI: PAUSED SCTE104 Paused by an SCTE-104 mute command
LEXI: PAUSED GPI-E Paused because the GPI-E trigger is inactive
LEXI: PAUSED UPSTRM Paused because upstream captions are present
LEXI: STOPPED SCTE Stopped by an SCTE-104 command
LEXI: STOPPED GPI-E Stopped because the GPI-E trigger went inactive
LEXI: STOPPED UPSTRM Stopped because upstream captions took over
LEXI: DISABLED No LEXI captioning job is currently running
Note. When iCap is active, the LEXI status overwrites the iCap status on line 2.

Video input and bypass, line 1

Message Condition
2160p60, 1080p50 and similar Normal operation. Shows the detected video format for each input
NO VIDEO! blinking No video signal is present on either input
Gen: as a prefix An internal generator signal is in use in place of live video
BYPASSED The unit is in relay bypass and video passes through without encoding. See section 4.3

Caption output status, line 3

This line reports the internal caption encoding state and is independent of the CC indicator. Where a channel is named, S1 or S2 is appended. Each message follows the prefix CC:, for example CC: LIVE S1 or CC: UPSTREAM.

Message Condition
BYPASSED Relay bypass is engaged at the ACTIVE control, so the unit is not encoding captions. Shown in capitals
LIVE Captions are actively being inserted on S1 or S2, or both
BRIDGING Caption bridging is active: captions arriving on one input are being copied to the other channel's output. See section 7.3.4
UPSTREAM No local caption source is active, so any captions already in the incoming signal pass through unmodified. This is the idle state, shown whenever nothing is captioning
MSTR 708 OUT OFF CEA-708 output has been disabled on the main output
AUX 708 OUT OFF CEA-708 output has been disabled on the auxiliary output
ALL 708 OUT OFF CEA-708 output has been disabled on both outputs
F1 UPSTRM BLOCK Upstream Field 1 captions are being blocked. Often seen when a LEXI job has started but has no audio to caption. See the Help Center
F2 UPSTRM BLOCK Upstream Field 2 captions are being blocked
F1F2 UPSTM BLCK Upstream Field 1 and Field 2 captions are both being blocked
708 BLOCKED CEA-708 captions are being blocked
708, F1 BLOCKED CEA-708 and Field 1 captions are being blocked
708, F2 BLOCKED CEA-708 and Field 2 captions are being blocked
ALL BLOCKED All caption types are being blocked
Note. The blocked and disabled messages describe deliberate configuration, not errors. They tell you the encoder is suppressing a caption path on purpose. The Help Center covers the case operators ask about most.

4.6 Navigation keypad

The keypad to the right of the display has six keys: four directional keys, a confirm key marked with a green check, and an exit key marked X.

Key Use
Up, Down Move through a menu, or change the value of the selected field
Left, Right Move between fields, or step back through the menu
Green check Open a menu, select an item, or confirm an entry. It behaves like the Enter key on a keyboard
X Leave the current screen without applying a change or return to the status screen. It behaves like the Escape key

Keys are momentary and register a single press; there is no key repeat when a key is held. Actuation force is 80 to 120 grams, that is 0.78 to 1.18 N.

The menu these keys move through is documented in section 7.

4.7 Cooling intake

The three grilles on the left of the panel are cooling air intake, drawing air across the electronics and exhausting it at the right side and rear. Keep them clear. Do not fit a front door or blanking panel that seals against the panel and check the grilles for dust at each maintenance visit.

7. Front panel menu reference

This section maps the front panel menu. It is a reference: use it to find where a setting lives and what its options are. Section 4.6 covers the keypad, and section 4.5 the status screen the menu returns to.

The menu exists so that a unit can be addressed before it is on the network and operated when the network is down. The web interface covers everything here and a great deal more.

Note. Every item in this section was read from the menu tables in the front panel display program on a unit.

7.1 Entering and leaving the menu

Key Marking Use
Up, Down Arrows Move through the items in a menu, or change the value of a selected field
Left, Right Arrows Move between the fields of value. This is how you enter an address one octet at a time
Confirm Green check Opens a menu and confirms an entry. It behaves like the Enter key on a keyboard
Exit X Leaves the current screen without applying a change. It behaves like the Escape key

Press the green check from the status screen to open the menu, and the X key to leave it.

Note. The left arrow steps back out of a submenu, but it will not leave the top level of the menu. Use the X key to return to the status screen from anywhere.

No setting in this menu requires the unit to be restarted. Changes apply when you confirm them. The one exception is a software update, which interrupts service and is documented before the operator uploads it.

7.2 Menu map

Menu What it covers Detail
System Setup Network addressing, front panel security, display legibility, the auxiliary output mode, the P1 serial mode, and unit identity 7.3
Audio Setup Peak level readout for each of the four audio programs 7.4
Decoder Setup How the monitoring decoder draws captions, and blanking of the decoder output 7.5
Utilities Test captions, return to upstream captions, and the internal video generator 7.6

The complete menu, every submenu and every option, is reproduced in Appendix A.

7.3 System Setup

7.3.1 Network

Addressing is configured separately for each Ethernet port. The interfaces are detected automatically. Either port gives full access to the unit; see section 3.3.

Parameter Options Notes
IP Address Entered by the operator Four octets, entered one at a time with left and right
Subnet Mask Entered by the operator
Gateway Entered by the operator
DNS Servers Configured, From DHCP Configured uses the servers set from this panel. From DHCP uses the servers the DHCP server supplies
Set Config Static, DHCP Selects whether the address above is used, or one is obtained from the network
MAC Address — Read only. The port's hardware address

Both lan1 and lan2 carry this identical set.

This menu is the one step in commissioning that cannot be done any other way, because the unit has no address until it is done.

7.3.2 Security

Parameter Options Notes
Security Mode Debug, Production See below
Reset Web Login Cancel, Reset now Returns every username and password to the factory login
Restore Certificate Cancel, Restore now Restores the unit's certificate

Security Mode governs which network services the unit answers.

Mode SSH, TCP port 22 PING, ICMP Web interface
Debug Available Available Available
Production Disabled Disabled Available

Production is the medium security setting and the one to leave a unit in for service. Debug opens SSH and PING for diagnosis.

Note. SSL is on by default for the web interface and for iCap, in both modes. Changing the security mode does not change that.
Caution. Reset Web Login returns all usernames to the factory eeg / eeg login. Anyone with physical access to the panel can perform it, so treat the rack room as part of the unit's security boundary. Set a new login immediately afterward.

Restore Certificate returns the unit to the Ai-Media default certificate, the one it shipped with. That certificate is generated by Ai-Media rather than being a generic self-signed certificate. Use it to recover from a bad certificate import. Any certificate you installed yourself is replaced, so keep a copy before running it.

7.3.3 LCD Display

Parameter Range
LCD Contrast 0 to 75
LCD Backlight 0 to 50

These are the only legibility adjustments available at the panel. They change how readable the existing characters are; they do not change the character size, which is fixed.

7.3.4 Aux Mon Output

Decoder or Dual Encode. Selects what the auxiliary output carries.

Setting What the auxiliary output carries
Decoder The monitoring decoder's rendering of the selected caption service, for a confidence monitor. Section 7.5 covers how that rendering looks
Dual Encode A second independently encoded program. The unit captions two video channels at once, embedding the same captions in both

About dual encoding. UHD592 can caption two independent video channels, embedding the same closed captions in each. Any two supported video standards can be combined on the inputs, and each output carries its own input's standard. If 1080p60 HD-SDI is present on the main input and 2160p60 UHD-SDI on the auxiliary input, the main output is captioned 1080p60 and the auxiliary output is captioned 2160p60.

Note. Selecting Dual Encode gives up the confidence monitoring output. An operator who relies on the decoder rendering to check captions visually will not have it while the unit is dual encoding; the caption status on the display and the web interface remain available.
Note. While the auxiliary output is set to Decoder, video arriving at AUX IN does not pass to the auxiliary output. Engaging relay bypass switches the auxiliary output back to the AUX IN video. See section 3.6.

Caption bridging. Bridging copies captions arriving on one input across to the other channel's output. It happens automatically when a captioned video input is connected to one input and a video signal with no caption data to the other. The front panel display indicates when the encoder is bridging; see section 4.5.1. Bridging is controlled by the ^Ah Smart Encoder command, which can be made persistent through Startup Settings.

7.3.5 P1 Mode

RS232, RS422 EEG or RS422 Sony. This is the mode of serial port P1, referred to in section 3.5. P2 has no mode setting at the panel.

7.3.6 Version

Read only. Use this to confirm what a unit in the rack is running.

Parameter Shows
Unit ID The unit's identifier
Build The software build
Firmware The firmware version
Device The device type

Section 1.1 explains where to read the unit’s software and firmware versions.

7.4 Audio Setup

Parameter Applies to Notes
Peak Level Program 0, Program 1, Program 2, Program 3 Read only

Peak Level is a readout, not a setting. It follows the audio embedded in the incoming SDI signal and displays it as a dBFS level, so the value moves continuously while audio is present.

Note. Audio input selection, gain, group and channel mapping are set in the web interface, not at the panel. The panel shows peak level only.

7.5 Decoder Setup

These settings control the built-in monitoring decoder, which renders captions onto the auxiliary output so an operator can see on-air captions on a confidence monitor. They do not affect the captions the encoder inserts into the program output.

Parameter Options
708 Font Default, Prop. Serif, Mono Sans, Prop. Sans
708 Size Default, Small, Standard, Large
708 Opacity Default, then 100 percent to 0 percent in steps of 10 percent
Blank Output Off, On

Blank Output blanks the decoder output only, putting house black on the auxiliary output. It is not the same control as the video generator in section 7.6.3, which puts house black on the encoder side at a resolution you select.

Caption text and background color are not adjustable.

7.5.1 Caption service selection

The monitoring decoder renders one caption service at a time. These are the services it can be set to, and what each one is.

Selection What it selects Notes
S1 CEA-708 service 1 The primary caption service. Carries the same captions as CC1 in a correctly authored stream
S2 CEA-708 service 2 Equivalent to CC3
S3 CEA-708 service 3 Equivalent to CC4
S4, S5, S6 CEA-708 services 4 to 6 CEA-708 only. These have no CEA-608 equivalent, so there is no CC selection above CC4
CC1 CEA-608 field 1, channel 1 The primary channel in United States practice
CC2 CEA-608 field 1, channel 2 Selectable, but not the United States convention. A stream that carries nothing on CC2 renders blank
CC3 CEA-608 field 2, channel 1 Conventionally the secondary language. Equivalent to S2
CC4 CEA-608 field 2, channel 2 Equivalent to S3
Note. In the United States the Caption pairs that matter are S1 with CC1 for the primary language and S2 with CC3 for the secondary. If a selection renders nothing, check that the incoming signal carries that service before treating it as a decoder fault.

These services are carried in the vertical ancillary data of the HD signal. SD Line 21 is not supported; see section 1.4.

Note. This selection is not made at the front panel. It is made in the web interface, under the configuration cog on the channel status page, in Caption Settings > Decoder Settings.

7.6 Utilities

7.6.1 Test Captions

Generates caption data inside the unit so the downstream path can be proved without a live caption source.

Parameter Options
Enable Off, On
Set Channel CC1, CC2, CC3, CC4
Note. Test captions replace local caption output. Line 2 of the status screen reads Test cap: while they are running, which is the reliable way to tell. LEXI takes priority over any local caption input, including test captions. Turn test captions off before the unit returns to service.

7.6.2 Force Regen

An action with no options. It returns the encoder to passing the captions that arrive with the incoming video and resets the caption input ports to their default standby state.

Running it blocks caption input from serial port P2 and from iCap. LEXI still takes priority if a LEXI job is running.

Use it when the encoder appears stuck in caption mode, for example when it is stripping field 1 or field 2 captions and will not stop. Force Regen clears that state.

Note. The menu labels this behavior as a return to line 21, which is the term for the caption line in a standard definition signal. On the UHD592 it means a return to upstream captions and works normally for HD captions. The unit passes standard definition video but does not support standard definition captions; see section 1.4. Be aware that with a standard definition input the panel can report the system as normal, which is a false positive, not a sign that SD captions are being handled.

7.6.3 Generator Resolution

Runs an internal video generator in place of the input signal, putting house black on the encoder side.

Option
Off Generator not running; the unit passes the input signal
1080i60, 1080p60, 2160p60 60 Hz family
1080i50, 1080p50, 2160p50 50 Hz family
Caution. The generator replaces program video. Leaving it running takes the input signal off air.

Appendix A. Front panel menu map

This is the complete front panel menu, in the order the menu presents it. Section 7 explains what each setting does and when to use it; this appendix is the quick lookup for where a setting lives.

System Setup

Menu Sub-menu Parameter Options / values Notes
Network lan1 IP Address (user-entered) Interfaces auto-detected
Subnet Mask (user-entered)
Gateway (user-entered)
DNS Servers Configured: servers set from this panel
From DHCP: supplied by DHCP, not set on this box, not editable here
Fallback servers: built-in public fallback, not your site DNS, not editable here
New server: 000.000.000.000 → opens Edit DNS Server
Set Config Static / DHCP
MAC Address Read-only
lan2 IP Address (user-entered)
Subnet Mask (user-entered)
Gateway (user-entered)
DNS Servers Configured: servers set from this panel
From DHCP: supplied by DHCP, not set on this box, not editable here
Fallback servers: built-in public fallback, not your site DNS, not editable here
New server: 000.000.000.000 → opens Edit DNS Server
Set Config Static / DHCP
MAC Address Read-only
Security Security Mode Debug / Production
Reset Web Login Cancel / Reset now
Restore Certificate Cancel / Restore now
LCD Display LCD Contrast 0 to 75
LCD Backlight 0 to 50
Aux Mon Output Decoder / Dual Encode
P1 Mode RS232 / RS422 EEG / RS422 Sony
Version Unit ID XXXX Read-only
Build x.x.x Read-only
Firmware x.xx Read-only
Device xxxx Read-only

Audio Setup

Menu Sub-menu Parameter Options / values Notes
Program 0 Peak Level Read-only
Program 1 Peak Level Read-only
Program 2 Peak Level Read-only
Program 3 Peak Level Read-only

Decoder Setup

Menu Sub-menu Parameter Options / values Notes
708 Font Default / Prop. Serif / Mono Sans / Prop. Sans
708 Size Default / Small / Standard / Large
708 Opacity Default, then 100% to 0% in 10% steps
Blank Output Off / On

Utilities

Menu Sub-menu Parameter Options / values Notes
Test Captions Enable Off / On
Set Channel CC1 / CC2 / CC3 / CC4
Force Regen (action: enables upstream line 21, no options)
Generator Resolution Off / 1080i60 / 1080p60 / 2160p60 / 1080i50 / 1080p50 / 2160p50

Appendix B. Verified video formats

These are the video standards the unit has been tested against, and what each surface reported during the test. Use the tables to confirm that what you are seeing on a format matches what the format is expected to do.

B.1 Captured video formats

Video standard Rate iCap video iCap audio, embedded Main input, web status Aux input, web status Main LCD Aux LCD Test captions, decoder out Valid video and audio, SDI out 1 Valid video and audio, SDI aux out
720p 50 Good Good 720p50 720p50 720p50 720p50 Good Good Good
720p 59.94 Good Good 720p60 720p60 720p60 720p60 Good Good Good
720p 60 Good Good 720p60 720p60 720p60 720p60 Good Good Good
1080i 50 Good Good 1080i50 1080i50 1080i50 1080i50 Good Good Good
1080i 59.94 Good Good 1080i60 1080i60 1080i60 1080i60 Good Good Good
1080i 60 Good Good 1080i60 1080i60 1080i60 1080i60 Good Good Good
1080psf 23.98 Rendering issue Good 1080p24 1080p24 1080p24 1080p24 Good Good Good
1080psf 24 Rendering issue Good 1080p24 1080p24 1080p24 1080p24 Good Good Good
1080psf 29.97 Rendering issue Good 1080p30 1080p30 1080p30 1080p30 Good Good Good
1080p 23.98 Rendering issue Good 1080p24 1080p24 1080p24 1080p24 Good Good Good
1080p 24 Rendering issue Good 1080p24 1080p24 1080p24 1080p24 Good Good Good
1080p 25 Rendering issue Good 1080p25 1080p25 1080p25 1080p25 Good Good Good
1080p 29.97 Rendering issue Good 1080p30 1080p30 1080p30 1080p30 Good Good Good
1080p 30 Rendering issue Good 1080p30 1080p30 1080p30 1080p30 Good Good Good
1080p 50 Good Good 1080p50 1080p50 1080p50 1080p50 Good Good Good
1080p 59.94 Good Good 1080p60 1080p60 1080p60 1080p60 Good Good Good
1080p 60 Good Good 1080p60 1080p60 1080p60 1080p60 Good Good Good
2160p 30 Good Good 2160p30 2160p30 2160p30 2160p30 Good Good Good
2160p 50 Good Good 2160p50 2160p50 2160p50 2160p50 Good Good Good
2160p 60 Good Good 2160p60 2160p60 2160p60 2160p60 Good Good Good
Note. Rendering issue is recorded against the video preview in the iCap client, not against the encoder. On every one of those formats the encoder reported the format correctly on the web page and on the display, the decoder output was correct, and both SDI audio outputs were valid.
Note. The unit reports 59.94 and 23.98 rates on the display and web page as 60 and 24. That is the normal shorthand and not a misread format.

B.2 Internal generator

With the internal generator running, the generator replaces the main channel only. The auxiliary channel continues to report its own video input, and the main display prefixes the format with Gen: to show the signal is generated. See section 7.6.3.

Generator standard Rate iCap video iCap audio Main input, web status Aux input, web status Main LCD Aux LCD Test captions, decoder out Valid video, SDI out 1 Valid video, SDI aux out
1080i 60 Black, good na 1080i60 Vid input Gen: 1080i60 Vid input Good 1080i60 1080i60
1080p 60 Black, good na 1080p60 Vid input Gen: 1080p60 Vid input Good 1080p60 1080p60
2160p 60 Black, good na 2160p60 Vid input Gen: 2160p60 Vid input Good 2160p60 2160p60
1080i 50 Black, good na 1080i50 Vid input Gen: 1080i50 Vid input Good 1080i50 1080i50
1080p 50 Black, good na 1080p50 Vid input Gen: 1080p50 Vid input Good 1080p50 1080p50
2160p 50 Black, good na 2160p50 Vid input Gen: 2160p50 Vid input Good 2160p50 2160p50
Was this article helpful?
0 out of 0 found this helpful